Specific construction
Use the sheet for the documented thickness, core and surface scope. Obtain matched evidence for alternatives.
Technical reference / 6 mm ABA programme For the trade
A construction-specific reference for our nominal 950 × 2400 × 6 mm reinforced hybrid wall-panel programme. Figures below come from the supplied technical data sheet dated 13 July 2026.

The reference product is an ABA foamed SPC panel intended for interior wall cladding in wet and dry areas. The outer layers and lighter centre form one engineered assembly. This page does not assign these results to every wall-panel product in the library.
The sheet reports water absorption and thickness swelling averages of no more than 0.7%, under their respective test methods. Joint water tightness is recorded separately as a pass after 24 hours under the specified manufacturer’s protocol.
Matt and PET surfaces have different micro-scratch classifications in the sheet. The stated fire classification is D-s3, d2 under EN 13501-1. Review the relevant construction, installation conditions and documentation against the requirements of the destination market.
Use the sheet for the documented thickness, core and surface scope. Obtain matched evidence for alternatives.
A laboratory result is not an unlimited service promise. Installation details, exposure and the tested assembly remain relevant.
A useful quotation starts with the construction and the intended market. These are the decisions we work through with your product team.
Prepare your specification ↗| Characteristic / method | Stated reference result |
|---|---|
| Nominal dimensions | 950 × 2400 × 6 mm; thickness tolerance ±0.3 mm. |
| Density / ISO 1183-1 | 0.85 ± 0.10 g/cm³. |
| Flexural properties / ISO 178 | Stress ≥12 MPa; modulus ≥1500 MPa. |
| Water absorption / ISO 62 | Average ≤0.7% in the stated test. |
| Thickness swelling / ISO 24336 | Average ≤0.7% in the stated test. |
| Joint water tightness | Pass: 24-hour manufacturer protocol, verified by the named testing laboratory in the source sheet. |
| Dimensional stability / ISO 23999 | Average length shrinkage ≤0.15%; stated exposure 60°C for 6 hours. |
| Reaction to fire / EN 13501-1 | D-s3, d2. |
| Fungi / ISO 846 | Grade 0 in the stated laboratory exposure. |
| Micro-scratch / EN 16094 | Matt: class ≤MSR-B2; PET: class ≤MSR-B5. |
| Colour fastness / EN ISO 105-B02 | Grade 6. |
| PET peel resistance / ISO 24345 | Average ≥170 N/50 mm; PET face only. |
Reference values are taken from the supplied July 2026 technical sheet. They apply to its documented construction and surface scope. Product-specific reports and scope are reviewed for each programme.
Questions from product teams
No. It is a reaction-to-fire classification with smoke and droplet sub-classifications. It is not a claim of non-combustibility or suitability for every building application.
No blanket coverage is claimed. Match the technical documents and any underlying reports to the exact construction, surface and programme being supplied.